Search results for "Surface characterization"

showing 2 items of 2 documents

Structure and Deformations of Pd−Ni Core−Shell Nanoparticles

2005

International audience; Homogeneous collections of Pd−Ni core−shell nanoparticles have been prepared by decomposition of metal−organic compounds and studied by several electron microscopy techniques: transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDS), high-resolution transmission electron microscopy (HRTEM), energy-filtered microscopy (EFTEM), and by X-ray photoelectron spectroscopy (XPS). The physical and chemical properties of the Pd shell are supposed to depend on its electronic properties, which are influenced by the presence of the Ni core and by the deformation in the Pd lattice. Here, the interfacial structure of Pd/Ni and the lattice deformations in t…

DECOMPOSITIONSTRAINMaterials science[ SPI.MAT ] Engineering Sciences [physics]/MaterialsNanoparticle02 engineering and technology010402 general chemistryOXIDATION01 natural scienceslaw.invention[SPI.MAT]Engineering Sciences [physics]/MaterialsCondensed Matter::Materials ScienceX-ray photoelectron spectroscopylawMicroscopyMaterials ChemistryLEISPhysical and Theoretical ChemistryHigh-resolution transmission electron microscopySpectroscopyBimetallic strip021001 nanoscience & nanotechnologyREACTIVITY0104 chemical sciencesSurfaces Coatings and FilmsINTERFACECrystallographySURFACE CHARACTERIZATIONChemical engineeringTransmission electron microscopyGROWTHMETALSElectron microscope0210 nano-technologyBIMETALLIC PARTICLES
researchProduct

Surface AFM microscopy of unworn and worn samples of silicone hydrogel contact lenses

2008

Abstract: Purpose. To evaluate the qualitative and quantitative topographic changes in the surface of worn contact lenses (CLs) of different materials using atomic force microscopy (AFM). Methods. The topography of five different CL materials was evaluated withAFM over a surface of 25 lm2 according to previously published experimental setup. Average roughness (Ra) and root mean square (Rms) values were obtained for unworn and worn samples. Results. The Ra value increased for balafilcon A (11.62–13.68 nm for unworn and worn samples, respectively), lotrafilcon A (3.67–15.01 nm for unworn and worn samples, respectively), lotrafilcon B (4.08–8.42 nm for unworn and worn samples, respectively), g…

SiliconSurface characterizationwearMaterials scienceContact LensesSurface PropertiesSiliconesBiomedical Engineering02 engineering and technologySurface finishMicroscopy Atomic ForceHydrogel Polyethylene Glycol DimethacrylateBiomaterialsAtomic force microscopyPolymer deterioration03 medical and health sciences0302 clinical medicineOpticsMaterials TestingMicroscopySurface roughnessComposite materialdegradationScience & TechnologyAtomic force microscopybusiness.industryHydrogelsLotrafilcon BContact lensSilicone hydrogelContact Lenses Hydrophilic021001 nanoscience & nanotechnologyContact lensPseudomonas aeruginosaWettability030221 ophthalmology & optometryWetting0210 nano-technologybusinessJournal of Biomedical Materials Research Part B: Applied Biomaterials
researchProduct